Manual reset is possible to operate only after return of pressure. If you are looking for danfoss usa product store and catalog which enables you to purchase our products then please select the usa product store button. Pressure switch kp 15, kp 17w, kp 17b, kp 25 danfoss. Data sheet pressure switch, type kp danfoss dcs mn 2016. Can be used with steam, air, gaseous and liquid media. Acb cartridge pressure switch is a small disc type pressure switch for use in refrigeration and air conditioning systems. Pressure switches displaying products 1 12 of 17 switch to grid view. Because they play an important safety role in these applications, its crucial that the automatic or manual reset functions operate perfectly so reliability and quality are paramount. R1 r124 r4a r22 r404a r407a r407c r407f r407h r422b r422d r438a r448a r449a r450a r452a r507a r5a r449b r515b. Pressure switch, kp34, 3 psig differential, manual reset, 1418 npt, kp series.
Danfoss dual high pressure switch kp7bs with manual reset for. Jun 11, 2010 pro refrigeration, incs technical support demonstrates how to adjust an danfoss dual pressure control. Kp kpi pressure switches offer a compact, robust design, and proven repeatable performance. Pressure limiters can be manually reset by pressing reset button when the pressure is equal to the cutout pressure minus fixed value of the differential. Pro refrigeration, incs technical support demonstrates how to adjust an danfoss dual pressure control. Jun 03, 2016 a hands on demonstration of how to adjust a pressure switch for commercial refrigeration. How to install a danfoss 6070 series thermostat duration. Low water pressure cutout switch square d m4 pressure switch w low pressure cutoff.
Pressure switches, type kp technical leafl et industrial automation ic. Cs pressure switches have a threepole switch and adjustable differential. Pressure switches with manual reset set the cutout pressure on the range scale. Kp15 models are dual switches fitted with an extra contact to give an independent low pressure trip signal. So the pressure switch must be manually reset by the user to enable restart of the equipment. The kp pressure switches can be used as safety switches. Installed new hp switch set for 375 psig checked amp draw on condensing fans both working and correct rotation rated at 2.
After operational stop, these units reset automatically. Restart pressure is equal to cutout pressure minus differential value. With an automatic reset dwk version, it is always possible for the system to be switched on again automatically after the pressure decreases by a. For high pressure switches the restart pressure is equal to cutout pressure minus differential. Kp pressure switches with auto reset are supplied with top cover. The kp series are suitable for gaseous media and air. Import data and price of danfoss under hs code 8536 zauba.
Danfoss kp series pressure switches for light industry. Danfoss rt pressure switch pressostat cse distributors. Pressure switch type kp refrigeration and air conditioning danfoss. Installation guide pressure switch kp 1, kp 2, kp 5. Kp5 models are single highpressure switches with changeover contacts. Data sheet pressure switch, kpu set point a predetermined value to which a switch is adjusted and at which it performs its intended function. How to calibrate and adjust a pressure switch learning. Kp pressure switches danfoss kp switches are used for regulating, monitoring and alarm systems in the industry. The deadband or reset or switching differential is the difference in the rising and falling pressures at which the pressure switch operates. Automatic reset a unit with automatic reset is restored to operational mode automatically data sheet pressure switch.
Low prices, fast delivery time and professional technical support. Rt110 new old stock 10d52 rt110 new old stock 10d52 danfoss kps 45 pressure switch 0603121 105. Kp pressure switches are available in ip30, ip44 and ip55 enclosures. Danfoss electrical pressure switches for sale ebay. C437e2002 honeywell c437e2002 manual reset, 1 to 26 w. Danfoss pressure switches are electromechanical controls and limiters, that control the pressure of air and liquids within a given pressure range. Danfoss bcp pressure controller danfoss distributors. The pressure switches are tted with singlepole changeover switch spdt. The switch is preset with both the cuton and cutoff pressure. Data sheet pressure switch and thermostat kp and kpi ic. The starting and stopping of a well water pump is typically controlled by a pressure switch similar to the one shown below. C pressure switch additive the c437d,e series 2000 gas pressure switches are pressureactuated switching devices used in industrial gas system applications for safety shutoff, pressure control, and differentialpressure control. Manual reset a unit with manual reset can only be restored to operational mode by activating the external reset button.
Rt121 0175156666 pressure switches are used in general industrial and marine sectors. Make offer new danfoss pressure controller switch rt 110. Switches for commercial refrigeration pressure switch. The 060214466 provide automatic limit protection or manual reset limit protection for pressure systems.
Danfoss kp15 highlow pressure with automanual reset switch. Automatic reset a unit with automatic reset is restored to. High pressure safety controls for this purpose are classified into three types. Data sheet pressure switch, type kp terminology reset 1. Danfoss 060214966 kp 34 auto reset pressure switch danfoss kp switches are used for regulating, monitoring and alarm systems in the industry. Set point a predetermined value to which a switch is adjusted and at which it performs its intended function. The cuton pressure is the low pressure that starts the pump and the cutoff pressure is the high pressure that turns off the. Danfoss kp15 highlow pressure with auto manual reset switch product code. Kp pressure switch commercial refrigeration danfoss. They provide automatic or manual reset limit protection. Danfoss kp35 pressure switches, regulate and monitor the pressure in.
The bcps innovative features include failsafe bellows, manual or automatic reset options, and an spdt contact system based on a micro switch. Data sheet pressure switch and thermostat kp and kpi. Switches for commercial refrigeration pressure switch danfoss. Kp pressure switches are recommended for gaseous media also water, but only when mounted directly on the pipe do not use capillary tube mounting. View and download danfoss rt 112 installation manual online. Manual reset units with manual reset can only be restored to operational. Manual reset for pressure limiters possible only by means. Danfoss kp35 pressure switches, regulate and monitor the pressure in air, marine, water and heating applications.
Danfoss kp pressure switches are used for regulating, monitoring and alarm systems in industrial applications. Danfoss highlow automanual reset switch pressure controls. Pressure switches and thermostats, type kp danfoss. View and download danfoss kp 15 installation manual online.
Units with manual reset can only be reset during operation by activation. The ashcroft b4 pressure switch may be used on virtually all industrial and oem applications. Pressure switch, differential pressure switch, type rt danfoss. The rt pressure switches series consist of a variety of ordinary controls including differential and neutral zone pressure controls, safety pressure controls for steam boiler plant, and gold plated failsafe controls for applications in which safety or economical consequences are critical factors. Set the cutout pressure on cutout scale range scale. Single setpoint, fixed deadband, spdt or single setpoint, fixed deadband, 2 spdt dpdt action vacuum thru 3000 psi. Ip55 to en 60529 iec 60529 ip55 is obtained when the kp pressure switches. Danfoss 060214866 kp34 manual reset pressure switch note.
Danfoss kp15 highlow pressure with automanual reset switch product code. The bcp type is a series of dedicated pressure switches for. Danfoss kp switches are used for regulating, monitoring and alarm systems in the industry. The pressure switches are fitted with singlepole changeover switch spdt.
Danfoss kp15 highlow pressure manual auto reset switch product code. How to adjust a pressure switchjdnel refrigeration youtube. View and download danfoss mp 54 installation manual online. Manual reset a unit with manual reset can only be restored to operational mode by activation of the external reset button. The plugandplay, din 43650acompliant electrical connections on top of the pressure controls meet the industry requirements. Acb cartridge pressure switch is a small disc type pressure switch for use in refrigeration and. Pressure switches danfoss kp15 highlow pressure with automanual reset switch danfoss kp15 highlow pressure with automanual reset switch product code. The position of the switch is determined by the pressure switch setting and the pressure at the connector.
Danfoss dual high pressure switch kp7bs with manual reset. Rt116 017520366 pressure switches are used in general industrial and marine sectors. Maximum working pressure the maximum working pressure is determined. Kp pressure switches danfoss kp switches are used for regulating, monitoring and alarm systems in. Danfoss rt pressure switches pressostat are used in general industrial and marine sectors. Do not use screwdriver to resume control operation after safety cutout, push reset knob as indicated. Data sheet cartridge pressure switch type acb and ccb pressure controls acb and ccb are compact disc type pressure switches with fixed setpoints for longstanding use in refrigeration and air conditioning systems. Danfoss highlow pressure switch with adjustable reset kp series kp2 0601120 lpauto. Kp pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. Danfoss highlow pressure switch with adjustable reset kp series kp1 0601103 lp manual. Kp15 models are dual switches fitted with an extra contact to give an independent lowpressure trip signal. Data sheet cartridge pressure switch type cb pressure controls cb series are compact disc type pressure switches with fixed setpoints for longstanding use in refrigeration and air conditioning systems. The latest equivalent by danfoss of the ps and psu is the cs pressure switch, please note the ranges are not the same so below we have offered an alternative nearest to the old settings, please click on the link to see the new ranges. If you continue, you will be logged in and forwarded to your default danfoss store.
Manual reset the manual reset mechanism does not allow the pressure switch to automatically reset after the switch has cut out. This is a setting that determines the amount of pressure change required to reset the switch to its normal state after it has tripped. Also please note for the psu equivalents do not come with relief valves, these have to be ordered. They provide automatic limit protection or manual reset limit protection for pressure systems. Pressure limiters can be manually reset by pressing reset button when the pressure is equal set point a predetermined value to which a switch is adjusted and at which it performs its intended function. Acb is as standard equipped with a 6 amp contact system with automatic or manual reset. Danfoss kp kpi pressure switches are designed for gaseous and liquid media some types are ul, csa and fm approved. Rt30aw pressure switch for rising pressure g12, ip66, auto reset.
We offer low prices, fast delivery time and professional technical support. Kp5 models are single high pressure switches with changeover contacts. Industrial pressure switches pressure controls danfoss. Very competitive prices, fast delivery time and professional technical support. Date hs code description origin country port of discharge unit quantity value inr per unit inr nov 10 2016. I can find the high pressure manual resets for r22410a but i can only find auto reset for the low pressure switches.
They are fitted with a singlepole switch changeover spdt, and can control singlephase ac motors of up to 2 kw directly. Units with manual reset can only be reset during operation by activation of the reset button. Click on the hyperlinks below to see pressure switch videos on the rc worst youtube channel. The rt single pressure switches series consist of a variety of ordinary controls including neutral zone pressure switches, safety pressure switches for steam boiler plant, and gold plated failsafe controls for applications in which safety or economical consequences are. The pressure switches are fitted with a manual switch that will lock the contact system in the open position independently of the pressure in the system. Pressure switches with manual reset set the cutout presure on the cutout scale range scale. Danfoss kpi pressure switches are used for regulating, monitoring and. If you have further questions about your pressure switch or your water system please do not hesitate to call our experts at 855. The difference between pressure cutout and pressure cutin.
726 44 1440 195 26 175 997 346 847 881 235 62 214 223 1382 1022 1287 1023 1356 653 58 286 957 855 860 667 1012 796 1277 549 154 710 178